Input mode Frequency
measurement
(
see also under 17.)
Simple frequency
measurement
INP A: Frequency input
I
NP B: no function
Differential measurement
[A – B]
INP A: Frequency input A
INP B: Frequency input B
Total measurement [A + B]
INP A: Frequency input A
INP B: Frequency input B
Frequency measurement with
direction detection [Quad]
INP A: Frequency input 0°
INP B: Frequency input 90°
Ratio measurement [A / B]
INP A: Frequency input A
INP B: Frequency input B
Percentage differential
measurement [(A-B) / A in %]
INP A: Frequency input A
INP B: Frequency input B
User input 1
User input 2
When the MPI input is activated
the display is “frozen” and
remains “frozen” until the MPI
input is deactivated.
Internally the frequency meter
continues running
(Display store).
When the MPI input is activated
the current frequency for the
preset that has just been
selected will be adopted as the
new preset value.
(See also 8.2.2)
Lock input
When the Lock input is activated
the programming is inhibited
When the Lock input is activated
the setting of the preset values is
inhibited.
When the Lock input is activated
the setting of the preset values
and the programming are both
inhibited
7.8.4.2 Main menu for configuration
Main menu for matching the input
pulses to the display.
Multiplication factor
can be programmed from
00.0001 to 99.9999 .The setting
00.0000 will not be accepted
Division factor
can be programmed from
01.0000 to 99.9999
A setting < 01.0000 will not be
accepted.
Display mode
Calculation and display of the
frequency / speed in 1/sec
Calculation and display of the
frequency / speed in 1/min
Decimal point setting
(determines the resolution)
0 no decimal place
0.0 1 decimal place
0.00 2 decimal places
0.000 3 decimal places
Moving average
Moving average calculated
AVG 2 over 2 measurements
AVG 5 over 5 measurements
AVG 10 over 10 measurements
AVG 20 over 20 measurements
Start delay
Programmable from 00.0 up to
99.9 sec.
At the start of a measurement the
measurement results within this
time-period are ignored.
Waiting time
Programmable from 00.1 up to
99.9 sec.
This value specifies how much
time should elapse, after the last
valid edge, before zero is to be
displayed.
7.8.4.3 Preset 1
See below 7.9.5.5
7.8.4.4 Preset 2
See below 7.9.5.6
Page 10
www.kuebler.com