User manual

count status = 0
R
eset to preset 2
Count mode ADDING with
automatic reset and Batch
c
ounter
O
utput 2 (timed signal) active
when main counter = preset
value 2
Automatic reset to zero when
main counter = preset 2
Batch counter counts the number
of automatic repetitions of preset
2
Output 1 active when Batch
counter
>
preset 1
Manual reset sets both counters
to zero.
Electrical reset sets only the
main counter to zero.
Count mode SUBTRACTING
with automatic reset and Batch
counter
Output 2 (timed signal) active
when main counter = zero
Automatic reset to preset 2 when
main counter = zero
Batch counter counts the number
of automatic repetitions of preset
2
Output 1 active when batch
counter
>
Preset 1
Manual reset sets main counter
to preset value 2 and batch
counter to zero
Electronic reset only sets the
main counter to preset value 2
Count mode ADDING with
automatic reset and Total
counter
Output 2 (timed signal) active
when main counter = preset
value 2
Automatic reset to zero when
main counter = preset value 2
Total counter counts all the count
pulses from the main counter
Output 1 active when total
counter
>
preset value 1
Manual Reset sets both counters
to zero
Electrical reset sets only the
main counter to zero
Count mode SUBTRACTING
with automatic reset and Total
counter
Output 2 (timed signal) active
when main counter = zero
A
utomatic reset to preset value 2
when main counter = zero
Total counter counts (sub from
preset value 1) all count pulses
f
rom main counter
O
utput 1 active when Total
c
ounter
<
zero
Manual reset sets both counters
to the preset values
Electrical reset sets only main
counter to preset value 2
Tracking Preset mode
When preset 2 is changed then
preset 1 automatically tracks it.
Reset to zero
Preset 1 relative to Preset 2
Tracking Preset mode with
automatic reset
When preset 2 is changed then
preset 1 automatically tracks it.
Reset to zer
o.
Automatic reset to zero when
main counter = preset value 2.
Preset 1 relative to Preset 2
For the subtracting modes (SUB, SUBAR,
SUBBAT and SUBTOT), a „Reset“ (via the
key or the input) resets the counter/the
time counter to a new preset value 2.
7.8.5.3 Main menu for configuration
Main menu for matching the input
pulses to the display.
Unit of time
Seconds
Decimal point setting determines
the resolution
Minutes
Decimal point setting determines
the resolution
Hours
Decimal point setting determines
the resolution
Hrs. Min. Sec.
Decimal point setting
(determines the resolution)
0 no decimal place
0.0 1 decimal place
0.00 2 decimal places
0.000 3 decimal places
Page 12