User manual

Set value
S
et value can be programmed
from 000000 to 999999
A previously programmed
d
ecimal point will be displayed
7.8.5.4 Main menu for reset mode
Main menu for setting the reset
mode
Reset mode
Manual reset (reset key) and
electrical reset (reset input)
No reset possible
(reset key and reset input
inhibited)
Only manual reset possible
(reset key)
Only manual reset possible
(reset key)
Electrical Reset:
Always resets only the main counter.
Manual Reset:
Resets the main counter (ACTUAL) and
auxiliary counters (BATCH or TOTAL), if the
value of the main counter or the value of an
auxiliary counters is shown on the display.
7.8.5.5 Main menu for Preset 1
Main menu Preset 1
Preset 1 ON/OFF
Preset 1 ON
Preset 1 OFF and no function
Output signal
ADD mode output operations:
permanent signal at Output 1,
becomes active when count
>
Preset 1
SUB mode output operations:
permanent signal at Output 1,
becomes active when count
<
Preset 1
ADD mode output operations:
permanent signal at Output 1,
becomes passive when count
>
Preset 1
SUB mode output operations:
permanent signal at Output 1,
becomes passive when count
<
P
reset 1
ADD mode output operations:
timed signal at Output 1,
b
ecomes active when count
>
P
reset 1. (Activation only in
positive direction)
SUB mode output operations:
timed output at Output 1,
becomes active when count
<
Preset 1 (Activation only in
negative direction)
ADD mode output operations:
timed signal at Output 1,
becomes passive when count
>
Preset 1. (Deactivation only in
positive direction)
SUB mode output operations:
timed output at Output 1,
becomes passive when count
<
Preset 1. (Deactivation only in
negative direction)
ADD mode output operations:
timed signal at Output1,
becomes active with positive
direction and when count
>
Preset 1 and subsequently active
with negative direction and when
count
<
Preset 1
SUB mode output operations:
timed signal at Output 1,
becomes active with negative
direction and when count
<
Preset 1 and subsequently active
with positive direction and when
count
>
Preset 1
ADD mode output operations:
timed signal at Output1,
becomes passive with positive
direction and when count
>
Preset 1 and subsequently
passive with negative direction
and when count
<
Preset 1
SUB mode output operations:
timed output at Output 1,
becomes passive with negative
direction and when count
<
Preset 1 and subsequently
passive with positive direction
and when count
>
Preset 1
Duration of timed signal of
Output 1
programmable from 00.01 to
99.99 sec.
Timed signal is post-triggered
e
n
g
l
i
s
h
Page 13