7.8.5.6 Main menu for Preset 2
Output signal
ADD mode output operations:
permanent signal at Output 2,
becomes active when count
>
Preset 2
SUB mode output operations:
permanent signal at Output 2,
becomes active when count
<
zero
ADD mode output operations:
permanent signal at Output 2,
becomes passive when count
>
Preset 2
SUB mode output operations:
permanent signal at Output 2,
becomes passive when count
<
zero
ADD mode output operations:
timed signal at Output 2,
becomes active when count
>
Preset 2 (Activation only in
positive direction).
SUB mode output operations:
timed signal at Output 2,
becomes active when count
<
zero (Activation only in negative
direction)
ADD mode output operations:
timed signal at Output 2,
becomes passive when count
>
Preset 2 (Deactivation only in
positive direction)
SUB mode output operations:
timed signal at Output 2,
becomes passive when count
<
zero (Deactivation only in
negative direction).
ADD mode output operations:
timed signal at Output 2,
becomes active with positive
direction and when count
>
Preset 2 and subsequently with
negative direction and when
count
<
Preset 2
SUB mode output operations:
timed signal at Output 2,
becomes active with negative
direction and when count
<
zero
and subsequently with positive
direction and when count >
zero
ADD mode output operations:
timed signal at Output 2,
becomes passive with positive
direction and when count
>
Preset 2 and subsequently with
negative direction and when
count
<
Preset 2
SUB mode output operations:
t
imed signal at Output 2,
becomes passive with negative
direction and when count <
zero
and subsequently with positive
direction and when count >
zero
Duration of timed signal of
Output 2
programmable from 00.01 to
99.99 sec.
Timed signal is post-triggered
Active:
Relays are activated when the preset
value is reached.
Passive:
Relays becomes de-energized when the
preset value is reached.
Timed outputs that have started are
not
aborted by a RESET.
8 Operation
8.1 Switching the display during
operation
Pressing the DOWN key or the
UP key once causes the name of
the currently selected display
function to be displayed for 2
sec. If within this time the DOWN
key or the UP key is pressed a
second time, then the display
switches to the next or previous
display function. This is
confirmed by displaying the new
name for a period of 2 sec. After
2 sec the count value that
corresponds to the selected
display function is displayed.
t = 2 sec
Main counter
Batch counter
Total counter
Preset 1
Preset 2
8.2 Setting the presets
8.2.1 Setting via front keys
Using the UP key or the DOWN
key, select the preset to be
changed, either PRES1 or
PRES2 (see 8.1).