User manual

8.4.2 Selecting the parameter sets
The parameter sets are selected
using the UP key and the DOWN
key.
Default parameter set 1
D
efault parameter set 2
Default parameter set 3
8.4.3 Accepting the setting
Pressing the ENTER key accepts
the current setting and returns to
the operating mode.
The text SAVE is shown in the
display for 2 sec.
8.4.4 Parameter Set Table
P.SET1 P.SET2 P.SET3
HLP.TXT. ON ON ON
SL.LANG. EN EN EN
FUNCT COUNT COUNT COUNT
INP.POL. PNP PNP PNP
FILTER ON OFF OFF
COUNT CNT.DIR UP.DN QUAD
MP.INP.1 LATCH LATCH SET
MP.INP.2 TEACH SET TEACH
LOC.INP. PROG PROG PROG
MODE ADD SUB TRAIL
FACTOR 01.0000 01.0000 01.0000
DIVISO. 01.0000 01.0000 01.0000
DP 0 0 0.00
SETPT. 000000 000000 0000.00
RES.MOD. MAN.EL MAN.EL MAN.EL
PRES.1 ON ON ON
PR.OUT1
T.OUT1 00.10
PR.OUT2
T.OUT2 00.10 00.10
9 Error Message
Err 1 Set value 0 not allowed
Err 2 Set value Preset 2 not allowed
Err 3
negative Teach-In value for Preset 1 not
permitted
Err 4 Zero or negative Teach-In value for
Preset 2 not permitted
E
rr 45 EEPROM error
10 Connections
10.1 Signal and Control Inputs
N°Designation Function
1 INP A Signal input A
2 INP B Signal input B
3 RESET Reset input
4 LOCK Keypad lock
5 GATE Gate input
6 MPI 1 User input 1
7 MPI 2 User input 2
8
AC: 24 VDC/80 mA
DC: U
B connected
through
Sensor supply
voltage
9 GND (0 VDC)
Common connection
Signal and Control
inputs
10.2 Supply Voltage and Outputs
N°Designation Function
10 Relay contact C.2
11 Relay contact N.O.2
12 Relay contact N.C.2
Output 2
13 Relay contact C.1
14 Relay contact N.O.1
15 Relay contact N.C.1
Output 1
16
AC: 90..260 VAC N~
DC: 10..30 VDC
Supply voltage
17
AC: 90..260 VAC L~
DC: GND (0 VDC)
Supply voltage
Page 16
www.kuebler.com