User manual

Problem Possible cause Solution
Water flows on the floor. The melting water outlet is
not connected to the evap-
orative tray above the com-
pressor.
Attach the melting water outlet
to the evaporative tray.
The temperature in the appli-
ance is too low/too high.
The temperature regulator
is not set correctly.
Set a higher/lower temperature.
The door is not closed cor-
rectly.
Refer to "Closing the door".
The food products' tem-
perature is too high.
Let the food products tempera-
ture decrease to room temper-
ature before storage.
Many food products are
stored at the same time.
Store less food products at the
same time.
The thickness of the frost is
greater than 4-5 mm.
Defrost the appliance.
The door has been opened
often.
Open the door only if necessa-
ry.
There is no cold air circula-
tion in the appliance.
Make sure that there is cold air
circulation in the appliance.
If the advice does not lead to
the desired result, contact the
nearest Authorised Service
Centre.
Replacing the lamp
CAUTION! Disconnect the plug
from the mains socket.
1. Pull the left side of the lamp cover with
your fingers to unlock it. Remove the
cover by pulling it towards yourself.
1
2
1
2.
Replace the lamp with one of the same
power and shape, specifically designed
for household appliances. The
maximum power is shown on the light
bulb cover.
3.
Install the lamp cover.
4.
Connect the plug to the mains socket.
5.
Open the door.
Make sure that the light switches on.
21