User's Manual

HD 4000 C / HD 6000 C
English
5.956-648 A10369 (06/98)
2. Connected Loads
D. Specifications
D4
HD 6000 C
1.967-045
HD 6000 C
1.967-045
with hot-water
accessory kit
2.638-697
Mains power:
Power type 3 ~ 50 Hz 3 ~ 50 Hz
Voltage V 400 400
Nominal load (max.)
with water temp. of 20°C
kW 15 15
Power supply cable mm² 4 x 10 4 x 10
Control cable mm² 5 x 1.5 5 x 1.5
Motor starter (type)
External pre-fusing
A
slow
50 50
Water:
Flow volume L/h 5600 5600
Max. supply temperature
°C 60 80
Min. flow pressure bar 2 2
Max. flow pressure bar 6 6
Supply line, nominal dia. mm 40 40
Cooling water:
Flow volume L/h 250 250
Supply temperature
°C approx. 10 to 18 approx. 10 to 18
Min. flow pressure bar 2 2
Max. flow pressure bar 8 8
Supply line, nominal dia. mm 15 15