HD 7/250 De Tr1 59633200 08/10
Please read and comply with these original instructions prior to the initial operation of your appliance and store them for later use or subsequent owners.
Burst disc If the working pressure exceeds the max. permissible overpressure by approx. 10%, the burst disc will be destroyed and the water will circulate inside the appliance without pressure. High pressure operation no longer possible. Pressure switch The pressure switch switches off the appliance if the minimum prepressure is not reached. High pressure sensor The pressure sensor monitors the pressure buildup in the high pressure system.
Device elements 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 Towing hitch Tear-off rope Connector vehicle lighting Support wheel Battery Battery main switch Block wedge Oil dip pump gear Covering lid, oil drain opening pump gear Oil drain screw intermediate gear Oil sight glass intermediate gear Ventilation screw intermediate gear Ventilation end gear Filling nozzle diesel tank Compressor Cover Compressed air valve Air filter Equalising reservoir motor coolant 20 21 22 23 24 25 26 27 28 29 30 31 32 33
Display and operating panel + 8 1 2 3 4 5 6 Display actual pressure Bar graph fuel level Bar graph water level in tank Display cooling water temperature Display oil pressure F6 key, menu preselection Symbols on the display Symbol Meaning Nominal pressure Actual pressure Motor oil pressure Fuel level Water level in tank 7 8 9 10 11 12 7 Key F5, increase nominal value Key F4, decrease nominal value Key F3, motor OFF Key F2, motor ON Key F1, reset key (acknowledge fault) Display appliance status
Operation Please observe Chapter "Safety Instructions" and the enclosed safety instructions for high pressure cleaners (5.063-314.0) Î Remove the chocks from underneath the wheels and place them in their holders. Î Release parking brake. Transport Trailer operation Note The driver, who operates the towing vehicle with trailer on public roads must ensure that he has the appropriate license for this.
Caution Do not completely deplete the fuel in the fuel tank, otherwise, the fuel system will have to be ventilated. Possibly suctioned dirt from the bottom of the tank can lead to malfunctions. Î Check the fill level of the diesel fuel at the bar segment display for the fuel level. If required, top off the diesel fuel. For temperatures below 0°, only use winter diesel. Check the fill level in the water tank Î Check the fill level of the water at the bar segment display for the water level in the tank.
Î Connect the water supply hose to the respective water inlet (arrow). Î Open the lock on the appliance cover and swivel the appliance cover upwards. Î Swivel the latch of the appliance hood upwards to keep it from shutting inadvertently. Î Check the water filter for contamination, clean/replace if required. Î Switch off the motor. Î Install the nozzle as described in the chapter "Connecting the nozzle". Settings + 8 7 The control voltage is switch on and the display shows the operating status.
Î By pressing the F6 key twice, you will return to the operating display. 0 ___ 155 ___ 210 Î Step 3: Press the F3 key to switch between brightness and contrast. Î You can change the brightness and contrast levels with the F4 and F5 keys. F4 (-) = set value decreases. F5 (+) = set value increases. Î By pressing the F6 key twice, you will return to the operating display.
Î Refill the antifreeze container with antifreeze. Select the mixing ratio of the water/antifreeze as per the instructions of the antifreeze manufacturer. Î Align the actuation lever of the ball tap for antifreeze/water tank vertically. Î Unscrew the high pressure hose from the high pressure outlet. The control voltage is switched on and the display shows the antifreeze rinse operation. Î Press the F2 key to start the motor. Î Let the motor run until antifreeze is visible in the antifreeze hose.
Maintenance and care – Danger – – 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 12 Maintenance Procedures may only be carried out by persons who have been instructed in the safe operation and maintenance on the high-pressure systems. Before carrying out any tasks on the machine, switch the key switch off and remove it. Prevent inadvertent startups of the appliance during Maintenance Procedures via third persons by attaching signs on the appliance and the spray unit.
Flow pattern 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 Compressor Oil cooler module Air cooler module Cyclone separator 2/2 way solenoid valve, 2-stroke Condensation drain, return to water tank Pressure relief valve Silencer Backflow valve Pressure regulation valve Ball tap Safety valve Pressure container Compressed air filter Pressure switch 2/2 way PN bypass valve 5/2 way valve 3/2 way valve Burst disc safety High pressure sensor 21 22 23 24 25 26 27 28 29 30 31 32 33 High-pressure pump Inter
Maintenance intervals Time Prior to each drive Activity Check the lighting. Check the tyre pressure and their state. Every 10 operating Check oil level in the pump gear (see "Initial startup"), refill oil if needed. hours or daily Check the water filter and clean if necessary. Check coolant level in the equalisation container (see "Initial startup"), refill coolant if needed. Once after the first 50 Replace motor oil (see "Maintenance Procedures"). operating hours Replace oil filter insert on motor.
Pump and gear Pump Mobil D.T.E Oil AA 320 Gear Mobil D.T.E Oil AA 320 Î The oil level is correct if it is within the markings on the oil dip. Î After the check, insert the oil dip and close the lid of the filler neck. Check the coolant and refill Note Prior to every operation, the fill level of the coolant in the equalisation container must be checked. Caution Observe the brand of antifreeze used. The mixture can cause a chemcial reaction and hazardous substances can be generated.
Î Read the fault message on the display and remediate the fault as per the table below. Î Press the reset button to acknowledge/ confirm the fault message. Faults Danger This can lead to severe injuries and possibly death. An improper startup and repair of the appliance and the spray unit is dangerous. Faults with display Faults detected by the control are shown on the display.
Display/meaning >Malfunction< High pressure sensor Cause Cable plug of high pressure sensor loose or short in connection Cable breakage High pressure sensor defective Remedy Check for correct fit By whom Operator Replace the cable Check / replace the sensor Customer Service Customer Service The permitted max.
Faults without display on the console 1 Fault Appliance stops, display switches off No display after switching the appliance on Main fuse Cause Main fuse is blown Remedy Replace the main fuse Battery main switch switched off Switch on the battery main switch Battery depleted Charging battery Main fuse is blown Replace the main fuse Motor will not start or See separate operating instructions of the motor turns off immediately Working pressure is Air in the high pressure pump Ventilating the high pressur
Accessories and Spare Parts – – – Only use accessories and spare parts which have been approved by the manufacturer. The exclusive use of original accessories and original spare parts ensures that the appliance can be operated safely and troublefree. At the end of the operating instructions you will find a selected list of spare parts that are often required. For additional information about spare parts, please go to the Service section at www.kaercher.com.
AE Karcher FZE, P.O. Box 17416, Jebel Ali Free Zone (South), Dubai, United Arab Emirates, +971 4 886-1177, www.kaercher.com AR Kärcher S.A., Uruguay 2887 (1646) San Fernando, Pcia. de Buenos Aires +54-11 4506 3343, www.karcher.com.ar AT Alfred Kärcher Ges.m.b.H., Lichtblaustraße 7, 1220 Wien, +43-1-25060-0, www.kaercher.at AU Kärcher Pty. Ltd., 40 Koornang Road, Scoresby VIC 3179, Victoria, +61-3-9765-2300, www.karcher.com.au BE Kärcher N.V., Industrieweg 12, 2320 Hoogstraten, +32-3-340 07 11, www.