Data Sheet

K2B24V10 Constant Current Time Profile @ 25°C
ADVANCED FEATURES
C/20
(0.48 A)
C/2
(4.8 A)
1C
(9.6 A)
2C
(19.2 A)
2.6C
(25 A)
20 hrs
Short Circuit
Protection
High Voltage
Cut Off
Low Votage
Cut Off
Cell
Balancing
Compatible with
most 24V Lead
Acid Chargers
2 hrs 60 min 29 min 24 min
Volts (V)
Capacity (mAh)
K2B24V10 Discharge Curves at Different Rates
2000
19.0
21.0
23.0
25.0
27.0
29.0
1A
4000 6000 8000 10000 12000
5A 15A 25A
DIMENSIONS:
*Cell balancing, low voltage cutoff, high voltage cutoff,
& short circuit protection
SPECIFICATIONS
RECOMMENDED OPERATING CONDITIONS
MAXIMUM OPERATING CONDITIONS
Nominal Capacity @ C/5 (Ah) 9.6
Average Operating Voltage@ C/5 (V) 25.6
Protection Control Module*
Weight (kg/lbs) 2.5 / 5.51
Height (mm/in) 165.0 / 6.57
Width (mm/in) 89.5 / 3.52
Length (mm/in) 115 / 4.53
Continuous Discharge (A) 9.6
Pulse Discharge (A) 30 Seconds 25
Charge Current (A) 4.8
Charge Voltage Cutoff (V) 29.2
Discharge Voltage Cutoff (V) 20.0
High Operating Temp (ºC) 55
Low Operating Temp (ºC) 5
Continuous Discharge (A) 24
Pulse Discharge (A) ≤2 seconds 40
Charge Current (A) 9.6
Max Modules in Series 1
Contact K2 about operating outside stated limits.
Performance may vary depending on application.
All specifications and operation conditions are subject to change without
notice. This data is for evaluation purposes only. No guarantee is intended
or implied by this data. MDS. P0008 REV-C. Engineering Part Number:
700575
UNDOT 38.3 Tested | RoHS Compliant
UL 2054 Certified | IEC 62133 Certified
HIGH CAPACITY K2B24V10EB ENERGY BATTERY DATA
K2 ENERGY SOLUTIONS INC 7461 EASTGATE RD HENDERSON NV 89011 702.478.3590 www.k2battery.com