Generated by Unregistered Batch DOC TO PDF Converter 2011.3.804.1511, please register! WALL-MOUNTED SPLIT AIR CONDITIONER KA AC 11 230V~ INSTRUCTION MANUAL Ref: 040929_GB Please read this instruction manual carefully before using the appliance and keep it for further reference. Contact our local qualified service centre, who will install your appliance. This appliance must be installed by a competent qualified technician.
Generated by Unregistered Batch DOC TO PDF Converter 2011.3.804.1511, please register! CONTENTS SAFETY INSTRUCTIONS............................................. 1 PARTS........................................................................... 3 OPERATION...................................……….................... 5 MAINTENANCE AND CLEANING................................ 8 TROUBLESHOOTING................................................... 9 INSTALLATION............................................
Generated by Unregistered Batch DOC TO PDF Converter 2011.3.804.1511, please register! SAFETY INSTRUCTIONS Read this safety awareness section carefully before use. The items indicated here are very important safety precautions, which must be followed. Must connect grounding line Strictly forbidden Must unplug plug Must be done WARNING Do not pull at the power cord. Hold plug to unplug when removing power, or part of the line in the power cord may break and cause fire.
Generated by Unregistered Batch DOC TO PDF Converter 2011.3.804.1511, please register! SAFETY INSTRUCTIONS WARNING Clean the air conditioner with a soft and dry cloth. Do not use chemical solvent, insecticide, inflammable -spraying material or which could damage the air conditioner. The appliance shall be installed in accordance with national wiring regulations. The appliance must not be installed in the laundry. The appliance must be installed 2.3m above the floor.
Generated by Unregistered Batch DOC TO PDF Converter 2011.3.804.
Generated by Unregistered Batch DOC TO PDF Converter 2011.3.804.1511, please register! PARTS Remote control Button functions On/Off Press this button to switch the appliance on and off. The remote control has a memory function, thus the setting information of last time will display on the control as long as you have the air conditioner always powered on. But if for instance you replace the batteries of the remote control, the stored information will be lost. Note: there is no memory for the sleep function.
Generated by Unregistered Batch DOC TO PDF Converter 2011.3.804.1511, please register! OPERATION Auto control Under auto operation, the microcomputer will produce the ideal environment according to the actual room temperature. Operation: 1. Press the "ON/OFF" button to switch on the air conditioner. 2. Press the "mode" button to choose the auto operation mode. 3. Press the "temp " buttons to set the temperature. 4. Press the "fan speed" button to set the fan speed. 5.
Generated by Unregistered Batch DOC TO PDF Converter 2011.3.804.1511, please register! OPERATION Timer setting Timer setting can set "ON" timer, "OFF" timer and "ON/OFF" timer. "ON" timer refers to when the air conditioner will start operating. "OFF" timer refers to when the air conditioner will turn to OFF position. "ON/OFF" timer refers to when the air conditioner will be on and off automatically. Before using the function, please set the clock on the remote control. Operation: Time adjustment 1.
Generated by Unregistered Batch DOC TO PDF Converter 2011.3.804.1511, please register! OPERATION Emergency button Please use emergency running when remote control is not available. 1. Press the emergency button when air conditioner is off, the air conditioner will start up and operate on auto mode, swing will work automatically. 2. Press the button when air conditioner is on, the air conditioner will shut. 3. When air conditioner is on "on time" or "off time", press the button to turn off the function.
Generated by Unregistered Batch DOC TO PDF Converter 2011.3.804.1511, please register! MAINTENANCE AND CLEANING Before cleaning, make sure the appliance has come to standstill and is unplugged. Cleaning the air filter 1. Clean the air filter once very two weeks. IF the air filter is dirty, the air conditioner will fail to work efficiently. 2. Open the cover of the air conditioner. 3. Take out the air filter. 4. Clean the air filter with dust cleaner or water, then dry it well. 5.
Generated by Unregistered Batch DOC TO PDF Converter 2011.3.804.1511, please register! TROUBLESHOOTING PROBLEM The appliance does not operate CAUSE Has the fuse broken out or has the circuit breaker been ripped? Is the power switch set to the off position? Is the "on time" setting mistaken? Has the air conditioner just been turned on for heating operation? Is the air conditioner defrosting? Is the filter dirty? See air filter cleaning instructions.
Generated by Unregistered Batch DOC TO PDF Converter 2011.3.804.1511, please register! INSTALLATION Installation and tubing 1.
Generated by Unregistered Batch DOC TO PDF Converter 2011.3.804.1511, please register! INSTALLATION 2. Drill hole on wall Drill 70mm hole on the left side or right side. 3. Install the wall-through pipe Insert the wall-through pipe into the hole. Have 15mm of pipe outside the wall. Use putty to seal the hole. 4. Direction of tubing Tubing can be connected in direction of 1,2,3,4,5. 5. Tubing connection Pull out the pipe of indoor unit and drainage hoses.
Generated by Unregistered Batch DOC TO PDF Converter 2011.3.804.1511, please register! INSTALLATION Air exhaustion, leakage-testing, pipes-wrapping and test-running 1. Exhaustion The moisture staying in cooling system could result in failure. Remove the screw cap of high-pressure valve and low-pressure valve. Remove the screw cap of the three way valve. Connect the joint of the vacuum pump to the maintenance point, fasten it (make sure it can lift up the pressure pin of the maintenance point).