Secure the mounting plate
The mounting plate should be attached to the structural part of the wall (post etc.).
NOTICE
The holes at solid arrow position must be secured to avoid the shake of mounting plate.
When the expansion bolts are used, two holes ( 11×20 or 11×26 ) that the distance
between them is 450mm should be adopted.
Drill on the wall
Confirm the position of holes, and drill holes of ф65mm on the wall.
Wiring
Open the front panel;
Remove the screw from the electrical box cover, pull the
electrical box cover away from the unit and set aside.
Remove the screw from the fastener, pull the fastener away
from the unit and set aside.
Connect the cable.
Replace the fastener and electrical box cover.
Diagram
Screw
Indoor unit terminal
Connecting cable
Connecting cable
Electric box cover
Screw
Fastener
Full the connecting cable’s
wire in completely
Fasten string at the central hole
Plumb