Operation Manual

(Fig. 1)
(Fig. 2)
(Fig. 3)
(Fig. 4)
(Fig. 5)
Installation drain hose
NOTE
The drain hose must be arranged beneath the copper pipe.
The drain hose must not be hunched or bent.
Do not wrap the drain hose by pulling it.
When the drain hose must be through the house, it should be wrapped
by the special heat insulated materials.
The copper pipe and the drain hose must be wrapped by felt strip. Heat
insulated pad should be used in the place that the pipe contact the wall.
ROUTE OF PIPE
REFIT OF DRAIN HOSE
If pipe came out of the right side of the indoor unit, cut part 1 on
the unit;
If pipe came out of the lower-right side of the indoor unit, cut part
"2" on the unit;
If pipe came out of the left side of the indoor unit, cut part 3 on
the unit.
If the pipe comes out of the left side of the indoor unit, the drain
hose must be refitted, otherwise water leakage may occur.
Refit methods: Interchange the position of drain hose and drain
rubber bib, the right diagram is un-refit position.
Clearance is not allowed after refit, it would lead to water leak.
Liquid pipe
Gas pipe
Adiabatic
underlay
Felt
Drain hose
Drain hose
Drain rubber
bid
Installation indoor unit
Let the pipe go through the wall hole and attach the
indoor unit to the mounting plate. (Locate the rib of
indoor unit in the hole of the mounting plate.)
Indoor unit
Bottom
The rib of indoor unit
The mounting plate
ARRANGEMENT OF DRAIN HOSE
To eject the condensate water easily, the drain hose should be declined downward. The arrangement in
diagram2-5 is wrong.
50mm or less
from floor
dip hose in water
water
leak
air
standing
water
decline
downward
decline
downward
water
leak
drain hose
hose (ID 15cm)
PVC hard
If the drain hose connected with the indoor unit is short, it may
be extended by the hose in the accessory box.
When the drain hose must be through the house, it should be
wrapped by the special heat insulated materials.