Manual

www.kamansensors.com PART NO: 860525-001
Last Revised 9/16/2013
- 25 -
Characterized with an aluminum target
2U 4U 9U 12U 16U 26U 38U 51U
Offset
inch 0.002 0.005 0.010 0.016 0.020 0.032 0.050 0.100
(mm) (0.05) (0.13) (0.25) (0.40) (0.50) (.80) (1.20) (2.50)
Short Range
inch 0.010 0.025 0.050 0.080 0.100 0.160 0.250 0.300
(mm) (0.25) (0.60) (1.25) (2.00) (2.50) (4.00) (6.00) (7.5)
Standard Range
inch 0.020 0.050 0.100 0.160 0.200 0.320 0.500 0.600
(mm) ('0.50) (1.30) (2.50) (4.00) (5.00) (8.00) (12.0) (15.0)
Extended Range
inch 0.030 0.070 0.150 0.240 0.320 0.500 0.800 1.000
(mm) (0.75) (1.75) (3.75) (6.00) (8.00) (12.5) (20.0) (25.0)
Typical Specifications for stardard range, aluminum target, standard cable length
Nonlinearity 6 pt calibration
±%FS <0.3%
Nonlinearity 21 pt calibration
±%FS <0.1%
Static Resolution
RMS%FS <0.001%
Resolution @ 100 Hz
RMS%FS <0.01%
Resolution @ 1000 Hz
RMS%FS <0.02%
Thermal Sensitity
%FS°F 0.05
(%FS°C) (0.1)
Thermal Sensitity w/temp
%FS°F 0.01
comp calibration
(%FS°C) (0.02)
Probe Specifications