Operations and Maintenance Manual

_
JANUS
®
Multi-Protocol Reader Ver. 2: Operating Instructions
Confidential UM 360463-202: A12 (Draft) Page 101 of 291
© Kapsch TrafficCom Canada Inc. 2014
These drawings and specifications contain confidential and proprietary information and are the property of Kapsch TrafficCom Canada Inc. and are issued in strict confidence and will be kept confidential and used solely for the purpose
intended and for no other purpose and shall not be transmitted, reproduced, copied, and/or used as the basis for manufacture or sale of apparatus unless otherwise agreed to in writing by Kapsch TrafficCom Canada Inc.
FILE: MPR2_OPERATIONS_AND_MAINTENANCE-MANUAL_REV A12.DOCX 05/08/2014 11:24
Kapsch TrafficCom
Command
How is this command
executed?
Who can
execute this
command?
Parameter
Name
Default
Parameter
Value
Parameter
Range/Options
What does this
command do?
What is the
purpose of this
command?
OBU Feedback tab
OBU Feedback
type
From the OBU Feedback tab on
the Configuration page:
With OBU feedback enabled,
select Type 1 or Type 2.
anyone
OBUTYP
0 (Type 1)
0 (Type 1)
1 (Type 2)
Specifies which type of
OBU feedback to employ:
TYPE1: all tags provide the
same feedback
TYPE2: determine what
feedback to use based on
a table lookup choose one
of:
0 - Type 1
1 - Type 2
to turn on and
specify which
type of feedback
an OBU provides
OBU Feedback Type 1
OBU Audible
Feedback
From the OBU Feedback tab on
the Configuration page:
With OBU feedback enabled
and Type 1 selected, select a
feedback option from the OBU
Audible Feedback drop-down
box.
anyone
OBUAUD
0 (Off)
0 (Off)
1 (4 cycles:
0.25s ON,
0.25s OFF)
2 (1 cycle: 1.5s
ON)
3 (3 cycles: 0.5s
ON, 0.2s OFF)
turns on and specifies the
type of audible feedback
an OBU provides
to configure how
long and how
many times an
OBU beeps to
indicate a
successful
transaction