Operations and Maintenance Manual

_
JANUS
®
Multi-Protocol Reader Ver. 2: Operating Instructions
Confidential UM 360463-202: A12 (Draft) Page 105 of 291
© Kapsch TrafficCom Canada Inc. 2014
These drawings and specifications contain confidential and proprietary information and are the property of Kapsch TrafficCom Canada Inc. and are issued in strict confidence and will be kept confidential and used solely for the purpose
intended and for no other purpose and shall not be transmitted, reproduced, copied, and/or used as the basis for manufacture or sale of apparatus unless otherwise agreed to in writing by Kapsch TrafficCom Canada Inc.
FILE: MPR2_OPERATIONS_AND_MAINTENANCE-MANUAL_REV A12.DOCX 05/08/2014 11:24
Kapsch TrafficCom
Command
How is this command
executed?
Who can
execute this
command?
Parameter
Name
Default
Parameter
Value
Parameter
Range/Options
What does this
command do?
What is the
purpose of this
command?
Not Available /
Internal Error:
Audible
From the OBU Feedback tab on
the Configuration page:
With OBU feedback enabled,
and Type 2 selected, select a
feedback option from the OBU
Audible Feedback drop-down
box.
anyone
O2NA_A
0 (Off)
0 (Off)
1 (4 cycles:
0.25s ON,
0.25s OFF)
2 (1 cycle: 1.5s
ON)
3 (3 cycles: 0.5s
ON, 0.2s OFF)
Specify the audible
feedback to provide for
a not available / internal
error
to configure how
long and how
many times an
OBU beeps to
indicate a
successful
transaction
Not Available /
Internal Error:
Visual
From the OBU Feedback tab on
the Configuration page:
With OBU feedback enabled,
and Type 2 selected, select a
feedback option from the OBU
Visual Feedback drop-down
box.
anyone
O2NA_V
0 (Off)
0 (Off)
1 (Green: 2s)
2 (Red: 2s)
3 (Yellow: 2s)
Specify the visual
feedback to provide in
the case of a not
available / internal error
to configure how
long and what
color an OBU LED
flashes to
indicate a
successful
transaction