FILE: MPR2_OPERATIONS_AND_MAINTENANCE-MANUAL_REV A12.DOCX 05/08/2014 11:24
Kapsch TrafficCom
Command
How is this command
executed?
Who can
execute this
command?
Parameter
Name
Default
Parameter
Value
Parameter
Range/Options
What does this
command do?
What is the
purpose of this
command?
Toll Rate Table
Select
From the Toll Rate/Balance tab
on the Configuration page:
with BAT 1 enabled, select one
of four toll rates from the Toll
Rate Table Select drop-down
box for each RF channel
click the Update TRBA
Configuration button
anyone
TRBATS
0 (Table 1)
0 (Table 1)
1 (Table 2)
2 (Table 3)
3 (Table 4)
sets the toll rate for each RF
Channel based on the
table selected
to allow a
Reader to charge
different rates,
depending on
which lane a
vehicle is in
Entry/Exit
Reader
From the Toll Rate/Balance tab
on the Configuration page:
with BAT 2 enabled, select
Entry Reader or Exit Reader
click the Update TRBA
Configuration button
anyone
TRBAER
0 (Entry
Reader)
0 (Entry
Reader)
1 (Exit Reader)
Entry Reader: This Reader
location is used as the
highway entry point when
calculating the toll
Exit Reader: This Reader
location is used as the
highway exit point when
calculating the toll
to allow a
Reader to charge
a different rate
on entry and exit
Enforce
Adjustment ID
Checking
From the Toll Rate/Balance tab
on the Configuration page:
select the Enforce Adjustment
ID Checking check box
click the Update TRBA
Configuration button
anyone
TRBEAI
0 (Disabled)
0 (Disabled)
1 (Enabled)
Disabled: no limits on
how often Reader can
update OBU balance
Enabled: limits how often
Reader can update OBU
balance
to set limits on
how frequently
the balance
stored in a
toll/balance OBU
can be updated.