Operations and Maintenance Manual

_
JANUS
®
Multi-Protocol Reader Ver. 2: Operating Instructions
Confidential UM 360463-202: A12 (Draft) Page 110 of 291
© Kapsch TrafficCom Canada Inc. 2014
These drawings and specifications contain confidential and proprietary information and are the property of Kapsch TrafficCom Canada Inc. and are issued in strict confidence and will be kept confidential and used solely for the purpose
intended and for no other purpose and shall not be transmitted, reproduced, copied, and/or used as the basis for manufacture or sale of apparatus unless otherwise agreed to in writing by Kapsch TrafficCom Canada Inc.
FILE: MPR2_OPERATIONS_AND_MAINTENANCE-MANUAL_REV A12.DOCX 05/08/2014 11:24
Kapsch TrafficCom
Command
How is this command
executed?
Who can
execute this
command?
Parameter
Name
Default
Parameter
Value
Parameter
Range/Options
What does this
command do?
What is the
purpose of this
command?
FDM Enable
From the Channel tab on the
Configuration page:
Select the FDM Enable
checkbox.
anyone
FDMEBL
0 (Disabled)
0 (Disabled)
1 (Enabled)
Disabled: TDM selections
not available to configure.
Enabled: FDM selections
available for
configuration.
Used for ATA,
6B, 6C, Sego
protocols
FDM RF State
From the Channel tab on the
Configuration page:
Select one of the choices
offered from the drop down
menu for every appropriate
channel.
anyone
RFFSTS
0 (Offline)
0 (Offline)
1 Active
2 Guard
3 Off
Offline means the frame
timing for this channel is
preserved, but the MRFM-
S module is off.
Active means the MRFM-S
module is on and reports
transactions on this
channel.
Guard means the MRFM-S
module is on, but
transactions assigned to
this channel are not
reported.
Off means the MRFM-S
module is off and the
framing is not preserved.
Used for ATA,
6B, 6C, Sego
protocols