Operations and Maintenance Manual

_
JANUS
®
Multi-Protocol Reader Ver. 2: Operating Instructions
Confidential UM 360463-202: A12 (Draft) Page 112 of 291
© Kapsch TrafficCom Canada Inc. 2014
These drawings and specifications contain confidential and proprietary information and are the property of Kapsch TrafficCom Canada Inc. and are issued in strict confidence and will be kept confidential and used solely for the purpose
intended and for no other purpose and shall not be transmitted, reproduced, copied, and/or used as the basis for manufacture or sale of apparatus unless otherwise agreed to in writing by Kapsch TrafficCom Canada Inc.
FILE: MPR2_OPERATIONS_AND_MAINTENANCE-MANUAL_REV A12.DOCX 05/08/2014 11:24
Kapsch TrafficCom
Command
How is this command
executed?
Who can
execute this
command?
Parameter
Name
Default
Parameter
Value
Parameter
Range/Options
What does this
command do?
What is the
purpose of this
command?
FDM Tag
Protocol
From the Channel tab on the
Configuration page:
Select one of the choices of
protocol offered from the list.
anyone
FDMPRT
0
0-5
Specify which FDM
protocol to use. choose
one of:
Off
SeGo (UID)
6B (UID)
6C (EPC)
ATA
SeGo (UID)+6C(EPC)
6B(UID,eATA)+6C(TID,EPC)
N/A
6C Skip Count
From the Channel tab on the
Configuration page:
When 6B+6C FDM Tag Protocol
is selected.
Anyone
6CSKIP
3
1-10
Defines how many times
the reader will attempt to
read 6B tags before
attempting to read a 6C
tag.
This allows the
reader to weight
6B tag reads
versus 6C tag
reads.