FILE: MPR2_OPERATIONS_AND_MAINTENANCE-MANUAL_REV A12.DOCX 05/08/2014 11:24
Kapsch TrafficCom
Command
How is this command
executed?
Who can
execute this
command?
Parameter
Name
Default
Parameter
Value
Parameter
Range/Options
What does this
command do?
What is the
purpose of this
command?
Dynamic Voting
Sample Size
From the Channel tab on the
Configuration page:
With Dynamic Voting Control
set to Reader, enter the
desired number of samples,
then, press Enter or select a
different tab.
user with
Advanced
User
permissions
DVSPSZ
20
1-50
Sets the sample size used
in the Dynamic Voting
Calculation
to configure the
Dynamic Voting
Control
calculation. The
number entered
here is the
number of
previous
transactions
used when
calculating the
average voting
time
Dynamic Voting
Threshold [%]
From the Channel tab on the
Configuration page:
With Dynamic Voting Control
set to Reader, enter the voting
threshold percentage in the
Dynamic Voting Threshold
field, then, press Enter or select
a different tab.
user with
Advanced
User
permissions
DVTHSD
20
5-100
sets the voting threshold
percentage
to configure
when the
average Voting
time is adjusted.
The Voting time
will only be
updated when
the Reader
determines the
percent change
is larger than the
threshold
entered here