Operations and Maintenance Manual

_
JANUS
®
Multi-Protocol Reader Ver. 2: Operating Instructions
Confidential UM 360463-202: A12 (Draft) Page 117 of 291
© Kapsch TrafficCom Canada Inc. 2014
These drawings and specifications contain confidential and proprietary information and are the property of Kapsch TrafficCom Canada Inc. and are issued in strict confidence and will be kept confidential and used solely for the purpose
intended and for no other purpose and shall not be transmitted, reproduced, copied, and/or used as the basis for manufacture or sale of apparatus unless otherwise agreed to in writing by Kapsch TrafficCom Canada Inc.
FILE: MPR2_OPERATIONS_AND_MAINTENANCE-MANUAL_REV A12.DOCX 05/08/2014 11:24
Kapsch TrafficCom
Command
How is this command
executed?
Who can
execute this
command?
Parameter
Name
Default
Parameter
Value
Parameter
Range/Options
What does this
command do?
What is the
purpose of this
command?
Dynamic Voting
Capture Zone
Span Multiplier
From the Channel tab on the
Configuration page:
With Dynamic Voting Control
set to Reader, enter a voting
time multiplier in the Dynamic
Voting Capture Zone Span
Multiplier field, then, press
Enter or select a different tab.
user with
Advanced
User
permissions
DVCZTM
2
1-5
sets the Capture Zone
Span Time multiplier
to determine
how long an
OBU has to be
out of a capture
zone before re-
entry is
considered a
new transaction.
This number is a
multiple of the
Average Voting
time
LC tab
Allow Remote
LC
Configuration
From the LC tab on the
Configuration page:
Select the Allow Remote LC
Configuration check box, then,
press Enter or select a different
tab..
user with
Advanced
User
permissions
RMOTLC
1 (Enabled)
0 (Disabled)
1 (Enabled)
Disabled: LC is not
permitted to Configure
Reader
Enabled: allows the LC to
configure the Reader
remotely
allows changes
to the Reader
configuration
from the LC