Operations and Maintenance Manual

_
JANUS
®
Multi-Protocol Reader Ver. 2: Operating Instructions
Confidential UM 360463-202: A12 (Draft) Page 120 of 291
© Kapsch TrafficCom Canada Inc. 2014
These drawings and specifications contain confidential and proprietary information and are the property of Kapsch TrafficCom Canada Inc. and are issued in strict confidence and will be kept confidential and used solely for the purpose
intended and for no other purpose and shall not be transmitted, reproduced, copied, and/or used as the basis for manufacture or sale of apparatus unless otherwise agreed to in writing by Kapsch TrafficCom Canada Inc.
FILE: MPR2_OPERATIONS_AND_MAINTENANCE-MANUAL_REV A12.DOCX 05/08/2014 11:24
Kapsch TrafficCom
Command
How is this command
executed?
Who can
execute this
command?
Parameter
Name
Default
Parameter
Value
Parameter
Range/Options
What does this
command do?
What is the
purpose of this
command?
LC Retry
Timeout
From the Serial tab on the
Configuration page:
Enter a time, in milliseconds, in
the LC Retry Timeout field,
then, press Enter or select a
different tab.
user with
Advanced
User
permissions
PROTTO
1000
50-1000
sets the LC retry timeout
to set the time
that the Reader
waits for LC
confirmation
before resending
data
Serial Port
State
From the Serial tab on the
Configuration page:
Select the Serial Port State
check box for the required LPM
COM port, then, press Enter or
select a different tab.
anyone
COM_ST
1 (Enabled)
0 (Disabled)
1 (Enabled)
Disabled: LCM COM port
disabled
Enabled: LCM COM port
enabled to communicate
with LC
to enable or
disable
communications
on each LPM
COM port
Baud Rate
From the Serial tab on the
Configuration page:
With the Serial Port State
enabled, select the desired
Baud Rate from the drop-down
box, then, press Enter or select
a different tab.
anyone
COM_BR
1 (19200)
0 (9600)
1 (19200)
2 (38400)
3 (57600)
4 (115200)
sets the LPM baud rate for
individual COM ports
to configure the
LPM baud rate
on a port by port
basis