Operations and Maintenance Manual

_
JANUS
®
Multi-Protocol Reader Ver. 2: Operating Instructions
Confidential UM 360463-202: A12 (Draft) Page 130 of 291
© Kapsch TrafficCom Canada Inc. 2014
These drawings and specifications contain confidential and proprietary information and are the property of Kapsch TrafficCom Canada Inc. and are issued in strict confidence and will be kept confidential and used solely for the purpose
intended and for no other purpose and shall not be transmitted, reproduced, copied, and/or used as the basis for manufacture or sale of apparatus unless otherwise agreed to in writing by Kapsch TrafficCom Canada Inc.
FILE: MPR2_OPERATIONS_AND_MAINTENANCE-MANUAL_REV A12.DOCX 05/08/2014 11:24
Kapsch TrafficCom
Command
How is this command
executed?
Who can
execute this
command?
Parameter
Name
Default
Parameter
Value
Parameter
Range/Options
What does this
command do?
What is the
purpose of this
command?
Select Logs
From the Ethernet Logging tab
on the Log Files page:
Select the check boxes of the
log files to be sent, then, click
the Update Ethernet Logging
Configuration button.
user with
View Log Files
and Manage
Log Files
permissions
ELLOGS
0 (trouble)
0 (trouble)
1 (tag)
2 (event)
3 (developer)
4 (debug)
5 (fifo)
sets which log files are
sent via Ethernet
to select only the
log files you
want to receive
Perform Tests
(serial comms)
From the Diagnostics Page:
Select the LPM COM port to be
tested from the Test
Enable/Disable drop-down
box, then, click the Perform
Test(s) button.
user with
Advanced
User
permissions
N/A
N/A
N/A
tests the specified LPM
serial port
to ensure that a
specified LPM
port is
functioning
properly when
troubleshooting
communication
problems with
the LC