Operations and Maintenance Manual

_
JANUS
®
Multi-Protocol Reader Ver. 2: Maintenance Instructions
Confidential UM 360463-202: A12 (Draft) Page 148 of 291
© Kapsch TrafficCom Canada Inc. 2013
These drawings and specifications contain confidential and proprietary information and are the property of Kapsch TrafficCom Canada Inc. and are issued in strict
confidence and will be kept confidential and used solely for the purpose intended and for no other purpose and shall not be transmitted, reproduced, copied, and/or
used as the basis for manufacture or sale of apparatus unless otherwise agreed to in writing by Kapsch TrafficCom Canada Inc.
FILE: MPR2_OPERATIONS_AND_MAINTENANCE-MANUAL_REV A12.DOCX 05/08/2014 11:24
Kapsch TrafficCom
Figure 5-3: LC Data Cable Installation
LC data cable installation ETHERNET 1 port, patch cable to solid conductor
8P8C
(RJ45)
CTM
LANE
CONTROLLER
Reader enclosure
lightning protector
CAT6 8 conductor, 24 AWG
LC data cable installation from LPM RS422
DB9
LPM
LANE
CONTROLLER
Reader enclosure
LC data cable installation from LPM RS232
DB9
LPM
LANE
CONTROLLER
Roadside Equipment LANE CONTROLLER
lightning protector
Maximum run limited by baud
rate, typically:
less than 50 feet at 9.6 Kb/s
Maximum run without a repeater
is limited by baud rate, typically:
less than 4000 ft at 19.2 Kb/s
less than 1700 ft at 115.2 Kb/s
Maximum run without a router,
hub or repeater is limited by
baud rate, typically:
less than 333 feet at 1 Gb/s
This consists of 300 ft of 24
AWG solid "horizontal" cabling
between the jacks at each end,
plus not more than 33 ft of 24
AWG stranded patch cable
between each jack and the
CTM.
*2 pair twisted
*2 pair twisted
TOLL PLAZA
* 2 pair twisted cable specified in the EIA RS232C,
CCITT V.55 and RS422 interface standards:
Conductor size and type: 24 AWG, twisted pair.
Nominal capacitance: 15.5 picofarads per foot
(between conductors of each pair); 27.5 picofarads
per foot (from each conductor to shield).
Nominal DC resistance (each conductor): 24.0
ohms per 1000 feet.
Nominal DC resistance (shield): 2.35 ohms per
1000 feet.
Shield type: Overall braided with drain wire.
Approval: Underwriters Laboratories (UL).
lightning protector
LC data cable installation ETHERNET 1 port, patch cable to fiber optic
8P8C
(RJ45)
CTM
LANE
CONTROLLER
Reader enclosure
fiber optic system
supplied by system
integrator
CAT6 8 conductor, 24 AWG
stranded patch cable
plus fiber optic
(fiber optic length dependant on
type chosen, typically 5000 ft)
and not more than 33 ft of 24
AWG stranded patch cable
between the fiber optic coupler
and the CTM.
jack
jack
patch patch
patch patch
fiber optic
coupler
fiber optic
coupler
Earth ground system
Earth ground system
Earth ground system