10. Using an SMA wrench, connect each RF Adapter Cable(s) (800125-001) SMA connector to the assigned
MRFM-S module port(s).
11. Tie all RF Adapter cables neatly and label both ends of each adapter cable, using marker tie wraps from
the label set (800498-001).
12. Secure the service loop portion of the feedline to the antenna-mounting bracket using the tie wraps. Do
not severely bend or kink the RF feedline cable.
Note: For a TDM only protocol configuration (i.e., no passive protocols), the Circulator can be located in
the cabinet with the reader and one RF feedline cable is connected between port 2 of the Circulator and
the antenna. Ports 1 and 3 of the circulator are then connected to the RF modules using the RF Adaptor
Cables (800125-001); see Figure 5-3.