_
JANUS
®
Multi-Protocol Reader Ver. 2: Maintenance Instructions
Confidential UM 360463-202: A12 (Draft) Page 170 of 291
© Kapsch TrafficCom Canada Inc. 2013
These drawings and specifications contain confidential and proprietary information and are the property of Kapsch TrafficCom Canada Inc. and are issued in strict
confidence and will be kept confidential and used solely for the purpose intended and for no other purpose and shall not be transmitted, reproduced, copied, and/or
used as the basis for manufacture or sale of apparatus unless otherwise agreed to in writing by Kapsch TrafficCom Canada Inc.
FILE: MPR2_OPERATIONS_AND_MAINTENANCE-MANUAL_REV A12.DOCX 05/08/2014 11:24
Kapsch TrafficCom
2. Assign an IP address to the parameter Ethernet 1 (LC 1Gbps) IP Address so that the Primary CTM is
accessible on the LC network, if necessary.
3. Assign an IP address to the parameter Ethernet 2 (IRIF 100Mbps) IP Address so that the Primary CTM
is accessible on the IR network, if necessary.
4. Assign an IP address to the parameter Reader IP Address for both primary and secondary CTMs on a
given Reader so that the Reader is accessible on the IR network, if necessary. This IP address is the
same for both CTMs in a Reader.
5. Assign an IP address to the parameter USB Adapter IP Address if a USB adapter is being used to
connect a CTM USB port to an Ethernet network.
6. Assign the gateway IP address to the parameter Default Gateway IP so that the Reader can
communicate via a gateway device such as a router, if necessary.
7. Press Enter to accept all addresses.
8. Repeat steps 1 through 7 for the secondary CTM.