Multi-Protocol Reader Ver. 2: Maintenance Instructions
Confidential UM 360463-202: A12 (Draft) Page 172 of 291
© Kapsch TrafficCom Canada Inc. 2013
These drawings and specifications contain confidential and proprietary information and are the property of Kapsch TrafficCom Canada Inc. and are issued in strict
confidence and will be kept confidential and used solely for the purpose intended and for no other purpose and shall not be transmitted, reproduced, copied, and/or
used as the basis for manufacture or sale of apparatus unless otherwise agreed to in writing by Kapsch TrafficCom Canada Inc.
FILE: MPR2_OPERATIONS_AND_MAINTENANCE-MANUAL_REV A12.DOCX 05/08/2014 11:24
Kapsch TrafficCom
3. In the Destination row, select the Ethernet check box for each RF channel that will communicate with
the LC via Ethernet.
4. Enter the LC IP address and Port number for each RF channel.
5. If all the RF channels will be communicating with the LC at the same IP address, enter the number of a
configured channel in the field beside the Duplicate button and then click Duplicate.
Result: All RF channels selected to communicate over Ethernet will now have the same destination LC
IP.
Note: When setting the LC Retry Timeout, consider the baud rate used to communicate with the LC and
the processing speed of the LC to avoid false failure reports.
6. Enter a time, in milliseconds, in the LC Ethernet TCP-Socket Timeout field.
7. Press Enter to accept your selections and inputs.
Note: If an LC does not respond within this time, the Reader will consider Ethernet communications to the
LC to be down and could trigger a switchover, depending on the redundancy settings.
Configuring the Ethernet 1 IP address via the Diagnostic Port
Contact Kapsch Service to set the ETHERNET 1 port IP address via the Diagnostic Port if the IP
address has been lost or cannot be determined.