2. Set the Dynamic Voting Control to Reader to allow the Reader to automatically set the voting time by
calculating the average capture zone span time.
3. Press Enter.
4. Enter a sample size in the Dynamic Voting Sample Size field. This is the number of previous
transactions the Reader includes when calculating the average capture zone span time.
Note: The Reader calculates the capture zone span time after each OBU transaction. The Reader will
not update the Dynamic Voting Time unless the capture zone span time changes more than the Dynamic
Voting Threshold percentage.
5. Enter a percentage in the Dynamic Voting Threshold field.
6. Press Enter or click outside the fields.
Result: The following screen appears.