Identifying failures on the primary and/or secondary side
Primary and/or Secondary side failure is indicated by any of the following conditions:
Ethernet LC link down, as indicated on the Reader browser Status page.
Ethernet IR network link down, as indicated on the Reader browser Status page.
Primary CTM MC or CGC LEDs are red
Serial LC link down, as indicated on the Reader browser STATUS page
Primary side failure is indicated by any of the following conditions
SPM switch is in PRIMARY position: primary CTM ACTIVE LED is red
SPM switch is in AUTO position: primary CTM ACTIVE LED is red
Secondary side failure is indicated by any of the following conditions:
SPM switch in any position: secondary MC or CGC LEDs are red
SPM switch is in SECONDARY position: secondary CTM ACTIVE LED is red
SPM switch is in AUTO position: primary CTM ACTIVE LED is red and secondary CTM ACTIVE
LED is red.
Events that cause an automatic switchover
Table 6-4 outlines the situations that can cause an automatic switchover and what settings need to be
configured for the trigger to be enabled.
Table 6-4: Switchover triggers
Event
Cause
Enabling
Failed CGC Health
The Reader continuously monitors the CGC
health and forces a switchover if health fails.
Automatic
Failed Serial Lane
Controller Link
The Reader forces a switchover when an
enabled serial link from the LPM to the LC
has been interrupted. Usually a downed link
is due to external conditions.
Only the lack of OBU transactions in outgoing
messages to the LC allows a downed link to
be detected. To detect serial cable issues in
the absence of OBU transactions, the
operator must enable Heartbeat messages
Must enable Switchover on
Serial Link Down from
General tab on
Configuration page
Must set LC Retry Timeout
from Serial tab on
Configuration page
Set Heartbeat messages from
LC tab on Configuration
page