be replaced by a spare CTM. The CTM is then sent to Kapsch Service to have its battery replaced.
MRFM-S replacement
The Reader does not need to be shut down to replace an MRFM-S.
Prerequisites: Connect the service laptop to the Reader configuration port to access the CTM web
interface. Refer to Connecting a service laptop to the Reader, page 40.
WARNING:
THE MODULES MAY HAVE SHARP EDGES. HANDLE THE MODULES
CAREFULLY. WHENEVER POSSIBLE, USE A MODULE EXTRACTION TOOL
TO REMOVE A MODULE.
WARNING:
THE MRFM-S MAY BECOME HOT UNDER NORMAL OPERATING
CONDITIONS. ENSURE THE MRFM-S HAS COOLED DOWN OR WEAR
GLOVES WHEN HANDLING THE MRFM-S.
Removing an MRFM-S
1. Select the Configuration link on the left side panel of the CTM web interface.
Result: The following screen appears.