Rebooting the CTM
This procedure outlines two ways of rebooting the CTM; using the ON/OFF switch on the CTM, and
using the Reboot button from the CTM web interface.
Prerequisites: To reboot from the browser interface, you must have Software Management
permissions.
Rebooting using CTM ON/OFF switch
1. Set the CTM ON/OFF switch to OFF.
2. After five seconds, set the CTM ON/OFF switch back to ON. The CTM POWER LEDs immediately
illuminate solid green. After 90 120 sec., the CTM STATUS LEDs illuminate their normal state (see LED
Status, page 192).
Rebooting from the browser interface
1. Login to the CTM web Interface.
Result: The following Main Page appears.
2. Select the Manage Software link on the left side panel of the CTM web interface.
Result: The following screen appears.