Manually select the active side and disable switchover
CAUTION:
If the primary or secondary side is forced active via the SPM redundancy
mode switch and that side fails, the Reader will not switch to the other
side and data could be lost.
1. Set the toggle switch on the SPM to the side to stay active, either SECONDARY or PRIMARY.
Result: This side is now active and no switchover will occur unlessa failure occurs.
Letting the Reader automatically choose the active side
1. Set the SPM toggle switch to AUTO.
Result: The primary side is now active by default, until a primary failure occurs.
Enabling the Reader to recover automatically to the primary side
1. Select the Auto Recovery to Prime check box then click the Update General Configuration button.
Result: The Reader will now automatically switch back to the primary side once a primary failure has
cleared.
Configuring the Reader to switch automatically over when an LC link is down
1. Select the Configuration link on the left side panel.
Result: The following screen appears.