Operations and Maintenance Manual

_
JANUS
®
Multi-Protocol Reader Ver. 2: Appendix
Confidential UM 360463-202: A12 (Draft) Page 263 of 291
© Kapsch TrafficCom Canada Inc. 2013
These drawings and specifications contain confidential and proprietary information and are the property of Kapsch TrafficCom Canada Inc. and are issued in strict
confidence and will be kept confidential and used solely for the purpose intended and for no other purpose and shall not be transmitted, reproduced, copied, and/or
used as the basis for manufacture or sale of apparatus unless otherwise agreed to in writing by Kapsch TrafficCom Canada Inc.
FILE: MPR2_OPERATIONS_AND_MAINTENANCE-MANUAL_REV A12.DOCX 05/08/2014 11:24
Kapsch TrafficCom
Technical Specifications and Pin outs
JANUS® Multi-Protocol Reader Ver. 2 Technical Specifications
Operation subject to FCC Site licensing (per FCC Part 90, Subpart M)
Dimensions (excluding enclosure)
Height = 17.5 inch
Width = 19.06 inch
Depth = 11.30 inch
Weight (excluding enclosure)
Redundant Reader, with all slots filled: 63 lbs. (Not including MRFM-S)
Enclosure Requirements
NEMA 4 rated
Operating Temperature Range
-29.2F to +165.2F (-34C to +74C) For operation above 55
o
C a 300CFM fan tray is required.
Power Requirements
300W @ 110VAC, UL/CSA power supply.
Minimum of two, 3-prong IEC-320 receptacles (not supplied).
PSM Ratings
95-135 VAC, 60 +/- 2 Hz, 5A.
One capable of supplying full load on redundant systems.
Software
Latest release available at delivery. Reader ships with default configuration settings.
Memory Capacity
400,000 buffered transactions.
RF Channel Capacity
Lane-based channels: maximum of 8.
ORT channels: maximum of 5.