Operations and Maintenance Manual

_
JANUS
®
Multi-Protocol Reader Ver. 2: Appendix
Confidential UM 360463-202: A12 (Draft) Page 264 of 291
© Kapsch TrafficCom Canada Inc. 2013
These drawings and specifications contain confidential and proprietary information and are the property of Kapsch TrafficCom Canada Inc. and are issued in strict
confidence and will be kept confidential and used solely for the purpose intended and for no other purpose and shall not be transmitted, reproduced, copied, and/or
used as the basis for manufacture or sale of apparatus unless otherwise agreed to in writing by Kapsch TrafficCom Canada Inc.
FILE: MPR2_OPERATIONS_AND_MAINTENANCE-MANUAL_REV A12.DOCX 05/08/2014 11:24
Kapsch TrafficCom
NEMA 4 Enclosure Specifications
Kapsch TrafficCom Field Cabinet Part Numbers
Left hinged: 800127-101
Right hinged: 800127-102
Dimension
Height = 36 inch
Width = 30 inch
Depth = 20 inch
Enclosure Requirements
A 6 to 8-inch clearance between the top and bottom of the Reader and enclosure.
Located for ready maintenance access.
Location limited by maximum RF and Synchronization cable run length.
Construction
-Aluminum with stainless steel components
-Neoprene gasket
-Installed a 19-inch equipment rack for Reader mounting
-Universally keyed lock
Penetrations
Must not allow moisture or condensation to run onto electronics or power cables.
Kapsch TrafficCom warranty extends to manufacturer defects as delivered but does not cover
environments, locations, or penetrations that invalidate the NEMA 4 rating.
Deference is made to any specifications used by the agency to govern NEMA 4 enclosures on its
roadways.
Grounding
Use AWG 8 wire to connect to the earth ground system.