Operations and Maintenance Manual

_
JANUS
®
Multi-Protocol Reader Ver. 2: Operating Instructions
Confidential UM 360463-202 Revision: A12 (Draft) Page 32 of 291
© Kapsch TrafficCom Canada Inc. 2014
These drawings and specifications contain confidential and proprietary information and are the property of Kapsch TrafficCom Canada Inc. and are issued in strict
confidence and will be kept confidential and used solely for the purpose intended and for no other purpose and shall not be transmitted, reproduced, copied, and/or
used as the basis for manufacture or sale of apparatus unless otherwise agreed to in writing by Kapsch TrafficCom Canada Inc.
FILE: MPR2_OPERATIONS_AND_MAINTENANCE-MANUAL_REV A12.DOCX 05/08/2014 11:24
Kapsch TrafficCom
Control Module (CTM)
Function
Contains the Reader processor
(MC), the Channel Group
Controller module (CGC).
Allows the CTM to be reset with
the CTM ON/OFF switch .
Controls when the RF modules
are interrogated.
X
Units per Redundant
Reader
One CTM on primary side,
One CTM on secondary side
Normal State
The POWER LED illuminates
green when the CTM is on and is
receiving power from the PSM.
The STATUS LEDs illuminate
green to indicate SYNC is
functional, CTM is active, CGC is
functional and MC is functional.
Connections
Port
Function
ETHERNET 1 - 1 Gbps
One option for connecting a service laptop directly
to the Reader,. or, for creating a network to connect
the Readers and LCs together.
ETHERNET 2 100 Mbps
For connecting several Readers together to create
an Inter-Reader (IR) network, or for connecting a
service laptop when Ethernet 1 is connected to the
Lane Controller.
DIAGNOSTIC PORT
A second option for connecting a service laptop
directly to the Reader. The browser interface cannot
be accessed from this port.
I/O