Operations and Maintenance Manual

_
JANUS
®
Multi-Protocol Reader Ver. 2: Operating Instructions
Confidential UM 360463-202: A12 (Draft) Page 76 of 291
© Kapsch TrafficCom Canada Inc. 2014
These drawings and specifications contain confidential and proprietary information and are the property of Kapsch TrafficCom Canada Inc. and are issued in strict confidence and will be kept confidential and used solely for the purpose
intended and for no other purpose and shall not be transmitted, reproduced, copied, and/or used as the basis for manufacture or sale of apparatus unless otherwise agreed to in writing by Kapsch TrafficCom Canada Inc.
FILE: MPR2_OPERATIONS_AND_MAINTENANCE-MANUAL_REV A12.DOCX 05/08/2014 11:24
Kapsch TrafficCom
Command
How is this command
executed?
Who can
execute this
command?
Parameter
Name
Default
Parameter
Value
Parameter
Range/Options
What does this
command do?
What is the
purpose of this
command?
System
Identification
From the Miscellaneous
Information tab on the Status
page:
Click the System Identification
button.
anyone
N/A
N/A
N/A
causes the CTM MC LED
to flash green-red-amber-
green three times
Used to confirm
which CTM web
interface is being
viewed and that
the computer is
successfully
communicating
with the CTM
Reset
Transaction
Statistics
From the Reports by channel
tab on the Statistics page:
Click Reset Transaction
Statistics button
user with
Advanced
User
permissions
N/A
N/A
N/A
sets all statistical values at
0
Used to allow
statistics to be
tracked from a
known starting
point
Site Name
From the General tab on the
Configuration page:
Type a Reader name in Site
Name text, then, click outside
the field, press Enter, or select
a different tab.
anyone
SITENM
no default
value
32
sets the site name used in
the log file strings and is
used in the name of the
configuration files
Used to identify
which Reader
the log files and
configuration
files originated
from
Ethernet 1 IP
(LC 1Gbps)
Address
From the General tab on the
Configuration page:
Type a ETHERNET 1 port IP
address in Ethernet 1 (LC
1Gbps) IP Address field, then, ,
click outside the field, press
Enter, or select a different tab.
anyone
LETHIF
192.168.1.50
N/A
sets the IP address for the
ETHERNET 1 port on the
CTM
Used to specify
an appropriate
ETHERNET 1 IP
address when
configuring an LC
network