Command
How is this command
executed?
Who can
execute this
command?
Parameter
Name
Default
Parameter
Value
Parameter
Range/Options
What does this
command do?
What is the
purpose of this
command?
Ethernet 2 IP
(IRIF 100Mbps)
Address:
From the General tab on the
Configuration page:
Type an ETHERNET 2 port IP
address in the Ethernet 2 (IRIF
100Mbps) IP Address field,
then, , click outside the field,
press Enter, or select a
different tab.
anyone
PRIMIP
192.168.0.50
Primary
192.168.0.51
Secondary
N/A
sets the IP address for the
ETHERNET 2 port on the
CTM
Used to specify
an appropriate
ETHERNET 2 IP
address when
configuring an IR
network
IP Address
From the General tab on the
Configuration page:
Type an IP address in IP
Address field in General tab of
the Configuration page, then, ,
click outside the field, press
Enter, or select a different tab.
user with
Advanced
User
permissions
SCNDIP
192.168.0.51
N/A
sets the IP address to the
secondary side of the
reader
Assigns a unique
IPv4 address
(e.g.
192.168.0.51) to
the secondary
side of the
reader. This
address should
be provided by
the SI network
planner.