Command
How is this command
executed?
Who can
execute this
command?
Parameter
Name
Default
Parameter
Value
Parameter
Range/Options
What does this
command do?
What is the
purpose of this
command?
Diagnostics
Port Baud Rate
From the General tab on the
Configuration page:
Select a baud rate from the
Diagnostics Port Baud Rate
drop-down box, then, , click
outside the field, press Enter,
or select a different tab.
anyone
DIAGBD
0 (9600)
0 (9600)
1 (19200)
2 (38400)
3 (57600)
4 (115200)
sets baud rate of
DIAGNOSTICS PORT on
the CTM
Used to establish
a baud rate for
connecting a
service laptop
computer to the
Reader via the
CTM
DIAGNOSTICS
PORT
Reader Sync:
Enable Reader
Sync
From the General tab on the
Configuration page:
Select the Enable Reader Sync
check box, then, , click outside
the field, press Enter, or select
a different tab.
anyone
RFSYNC
0 (Disabled)
0 (Disabled)
1 (Enabled)
Disabled: Reader RF
interrogation is not
synchronized with other
Readers
Enabled: Reader RF
interrogation is
synchronized with other
Readers in the sync
network
Used to
synchronize
superframes
between
Readers
connected
together in a
synchronization
network