Operations and Maintenance Manual

_
JANUS
®
Multi-Protocol Reader Ver. 2: Operating Instructions
Confidential UM 360463-202: A12 (Draft) Page 87 of 291
© Kapsch TrafficCom Canada Inc. 2014
These drawings and specifications contain confidential and proprietary information and are the property of Kapsch TrafficCom Canada Inc. and are issued in strict confidence and will be kept confidential and used solely for the purpose
intended and for no other purpose and shall not be transmitted, reproduced, copied, and/or used as the basis for manufacture or sale of apparatus unless otherwise agreed to in writing by Kapsch TrafficCom Canada Inc.
FILE: MPR2_OPERATIONS_AND_MAINTENANCE-MANUAL_REV A12.DOCX 05/08/2014 11:24
Kapsch TrafficCom
Command
How is this command
executed?
Who can
execute this
command?
Parameter
Name
Default
Parameter
Value
Parameter
Range/Options
What does this
command do?
What is the
purpose of this
command?
Switchover on
Serial Link
Down
From the General tab on the
Configuration page:
With Serial communications
enabled, select the Switchover
on Serial Link Down check box,
then, click outside the field,
press Enter, or select a
different tab.
user with
Advanced
User
permission
SOSERL
0
0-1
Disabled: switchover does
not occur when the Serial
link is down.
Enabled: Enable means
switch-over to secondary
side if the reader
determines a serial link to
the lane controller is
down. Has no meaning on
secondary side.
NOTE: If
enabled, you
MUST also
disable all
unused COM
ports (see
SERIAL tab) as
well as unused
LC destinations
(see LC tab).
Switchover on
Ethernet LC
Link Down
From the General tab on the
Configuration page:
With Ethernet LC
communications enabled,
select the Switchover on
Ethernet LC Link Down check
box, then, click outside the
field, press Enter, or select a
different tab.
user with
Advanced
User
permissions
SO_ETH
0
0 (Disabled)
1 (Enabled)
Disabled: switchover does
not occur when the
Ethernet LC link is down.
Enabled: to enable the
Reader to switchover
from the primary side to
the secondary side when
an Ethernet link to the LC
is down
N/A