Operations and Maintenance Manual

_
JANUS
®
Multi-Protocol Reader Ver. 2: Operating Instructions
Confidential UM 360463-202: A12 (Draft) Page 99 of 291
© Kapsch TrafficCom Canada Inc. 2014
These drawings and specifications contain confidential and proprietary information and are the property of Kapsch TrafficCom Canada Inc. and are issued in strict confidence and will be kept confidential and used solely for the purpose
intended and for no other purpose and shall not be transmitted, reproduced, copied, and/or used as the basis for manufacture or sale of apparatus unless otherwise agreed to in writing by Kapsch TrafficCom Canada Inc.
FILE: MPR2_OPERATIONS_AND_MAINTENANCE-MANUAL_REV A12.DOCX 05/08/2014 11:24
Kapsch TrafficCom
Command
How is this command
executed?
Who can
execute this
command?
Parameter
Name
Default
Parameter
Value
Parameter
Range/Options
What does this
command do?
What is the
purpose of this
command?
TC Date/Time
From the Tag Programming tab
on the Configuration page:
With TCP enabled, select TC
Date/Time.
anyone
TCDTTM
0 (Disabled)
0 (Disabled)
1 (Enabled)
Disabled: Reader
Date/Time not written to
OBU TC data fields.
Enabled: Reader
Date/Time written to OBU
TC data fields.
to keep a record
in OBUs of the
TC transaction
time
RW Format
From the Tag Programming tab
on the Configuration page:
With TCP enabled, select the
RW Format check box.
anyone
RW_FMT
0 (Disabled)
0 (Disabled)
1 (Enabled)
Disabled: RW Format not
affected
Enabled: Reader controls
how OBU scratchpad
memory is encoded
determines how
the data stored
in OBU
scratchpad
memory is
encoded
Lane Number
(enable)
From the Tag Programming tab
on the Configuration page:
With TCP enabled, select the
Lane Number R/W check box,
then, press Enter or select a
different tab.
anyone
enables lane number
programming
to enable ability
to set a specific
lane number for
each RF channel