Kapsch TrafficCom
Superframes
The available RF Air time is divided into frames. A series of frames is assembled into a superframe
which can be used to sync multiple readers together. In some configurations, a series of superframes
is assembled into a megaframe which is used to sync multiple readers together. A frame can be either
a TDM or FDM period. A superframe can be a collection of TDM and/or FDM frames.
Multi-protocol RF Module Smart
The Multi-protocol RF Module Smart (MRFM-S) can handle multiple passive tag protocols; 6B (ISO
18000-6 Type B), 6C (ISO 18000-6 Type C), ATA (10374/ATA/AAR S-918) SeGo and Allegro,as well
as the active protocol IAG.
The MRFM-S design includes a software command for adjusting the transmitter peak output power.
When installing or replacing an MRFM-S, the lane must be retuned.
The MRFM-S transmits a message to the CGC. After the message is processed by the CTM, a
message is sent to the LC.
The signals between the MRFM-S and the DSM are shown in Table 4-1.
Table 4-1: MRFM-S signals to and from DSM
Signal
Description
data input from DSM
Tx DA signals, RS422 bi-polar AM envelope modulation signals
data output to DSM
Rx DA signals, RS422 bi-polar AM envelope demodulation signals
RF control
Rx EN and Tx EN , RS422 bi-polar transceiver enable signals
RF control
A0 and A1 , RS422 bi-polar data address enable signals
power input from DSM
+5VDC (Vcc), +15VDC
The serial communication settings for the LC COM port are configurable through the web interface.
Power Supply Module (PSM)
The PSM AC mains power requirement is 95-135VAC (60Hz+/-2 Hz) at 10A max input current.
The PSM is field replaceable and provides:
A power switch and a 10A fuse