Figure 5-6: RF Cable Installation Schematic Bi-Static Operation
Use of the RF amplifier
The maximum cable loss and associated maximum cable length, as defined in the RF Cable
Specifications on page 265, is based on the output power of the MRFM-S module and the sensitivity of
the transponders. When the site specific application exceeds the limits defined on page 265, an
amplifier assembly can be used to effectively increase the output power of the MRFM-S module an
additional 6dB. This 6dB is then used to increase the maximum cable loss permitted as defined on
Page 265.
Use of this amplifier should be reviewed with Kapsch personnel before implementation. Figure 5-7
shows a typical installation that includes the use of the power amplifiers.