Operations and Maintenance Manual

_
JANUS
®
Multi-Protocol Reader Ver. 2: Maintenance Instructions
Confidential UM 360450-210 Revision C Page 180 of 288
© Kapsch TrafficCom Canada Inc. 2014
These drawings and specifications contain confidential and proprietary information and are the property of Kapsch TrafficCom Canada Inc. and are issued in strict
confidence and will be kept confidential and used solely for the purpose intended and for no other purpose and shall not be transmitted, reproduced, copied, and/or
used as the basis for manufacture or sale of apparatus unless otherwise agreed to in writing by Kapsch TrafficCom Canada Inc.
FILE: UM 360450-210 REV C JANUS MPR2 OPERATOR-MAINTENANCE MANUAL.DOCX 08/17/2015 11:42
Kapsch TrafficCom
Configuring synchronization
Prerequisites: Connect the service laptop to the Reader configuration port to access the CTM web
interface. Refer to Connecting a service laptop to the Reader, page 47.
Note: Reader synchronization also enabled remotely by the LC if the Remote LC Configuration is enabled.
1. Select the Configuration link on the left side panel.
2. Select the Enable Reader Sync check box, if necessary.
Result: The synchronization settings appear.
3. Select Sync to Every Superframe in the Superframe Sync Skip row.
4. Select No in the Add 2 Dummy Frames row.
5. Select JANUS from the drop-down box in the Type of Reader Synching To row.
6. Repeat these steps for all Readers in the Synchronization circuit.