Operations and Maintenance Manual

_
JANUS
®
Multi-Protocol Reader Ver. 2: Maintenance Instructions
Confidential UM 360450-210 Revision C Page 183 of 288
© Kapsch TrafficCom Canada Inc. 2014
These drawings and specifications contain confidential and proprietary information and are the property of Kapsch TrafficCom Canada Inc. and are issued in strict
confidence and will be kept confidential and used solely for the purpose intended and for no other purpose and shall not be transmitted, reproduced, copied, and/or
used as the basis for manufacture or sale of apparatus unless otherwise agreed to in writing by Kapsch TrafficCom Canada Inc.
FILE: UM 360450-210 REV C JANUS MPR2 OPERATOR-MAINTENANCE MANUAL.DOCX 08/17/2015 11:42
Kapsch TrafficCom
Table 5-3: Synchronization Compatibility Matrix JANUS
®
and BADGER
JANUS
®
Reader
superframe size
Superframe Sync
Skip Setting
Add two
dummy
frames Setting
BADGER
Reader
superframe size
Badger Sync
(fixed)
Badger
dummy
frames
(fixed)
8 frames
sync to every
superframe
No
4 frames
sync to every
other
superframe
No
10 frames
sync to every
superframe
Yes (with 8
active or
offline RF
channels)
5 frames
sync to every
other
superframe
No
The Ethernet Network
These are general instructions for using Ethernet Switch Modules (ESMs) to create an Inter-Reader
(IR) Ethernet network or a Lane Controller (LC) Ethernet network.
Installing an Ethernet network
Prerequisites: ESMs mounted according to the manufacturer’s instructions.
1. Use CAT 6 Ethernet cables to connect the components in the Ethernet network together as shown in the
examples in Figure 5-10. Consult the ESM manufacturer’s instructions for more details.