Figure 6-2: Typical MRFM-S Heartbeat message
Table 6-6: MRFM-S fault codes
Testing the CTM Ethernet 1 port
This test verifies that a CTM Ethernet 1 port is working properly.
Prerequisites: A service laptop.
1. Connect a service laptop directly to CTM Ethernet 1 port being tested (see Connecting a service laptop to
the Reader, page 47).
Note: Ensure that you can access the CTM web interface with the service laptop (see Accessing the CTM
web interface, page 47). This confirms the Ethernet port is functional.
Testing an LPM COM port
This test verifies that an LPM port is working properly and requires a simple loop-back connector.
Prerequisites: Connect the service laptop to the Reader configuration port to access the CTM web
interface. Refer to Connecting a service laptop to the Reader, page 47. You must have Advanced User
permissions.
Note: All OBU transactions on this port are buffered while the LC is disconnected from the LPM ports to
perform the test.
1. Disconnect the serial cable from the LPM COM port being tested.
Byte number
Value
Meaning
Byte 4
10000000
normal lane operation
Byte 4
10000001
lane hardware fault
Byte 3
00000000
normal lane operation
Byte 3
00000001
no activity on backplane control lines