Testing the Synchronization hub cabling
2. If the SYNC LED on the CTM does not illuminate solid green with a functional SPM and CTM connected to the
Synchronization circuit, the problem is with the wiring between the SPM and the synchronization hub terminal
block.
Testing the MRFM-S slots
The following test is to verify that all MRFM-S slots in the upper portion of the Reader rack are
functional.
Prerequisites: Connect the service laptop to to access the CTM web interface. Refer to Connecting a
service laptop to the Reader, page 47. One functional MRFM-S is installed in the RF slot 1 of the
Reader rack.
1. Select the Configuration link on the left side panel.
2. Click the Channel tab.
Result: The following screen appears.
3. Set Ch# (where the RF module is installed) to Active.
4. Ensure that the DATA LED on the RF module illuminates solid green.
5. From the Channel tab on the Configuration page, select Offline from the RF State drop-down box.