Saving the Reader configuration
Each CTM has a unique configuration file stored on its CFM. This configuration file can be downloaded
and saved to a computer. Use a saved configuration file to do the following.
Quickly configure another Reader requiring the same or similar configuration.
Restore the Reader to a known configuration.
Troubleshoot problems by comparing the current configuration to past configurations.
This procedure outlines the steps for saving the Reader configuration to a service laptop which is
logged into a CTM.
Prerequisites: A service laptop connected to Ethernet 1 or a USB port of the CTM and accessing the
CTM web interface. Refer to Connecting a service laptop to the Reader, page 47.
1. Click the Configuration link on the left side panel.
2. Click the Manage Config tab on the Configuration page.
Result: The following screen appears.
3. Click the Save config button to save the new configuration.
Note: Different ways to save the configuration file appear depending on the web browser you use.
Uploading a saved configuration
Uploading a saved configuration will overwrite the current Reader configuration. There are two options
for uploading a saved configuration: updating all configuration settings except for the IP settings, or
updating all configuration settings including the IP settings. All callouts refer to Error! Reference
ource not found..
Prerequisites: A service laptop connected to Ethernet 1 or a USB port of the CTM and accessing the
CTM web interface.Refer to Connecting a service laptop to the Reader, page 47. A version of the
configuration file to be loaded is saved on a service laptop connected to the Reader.
CAUTION:
Improper modification of configuration parameters may adversely
affect system operation. The default values may not be appropriate
for the specific application. It is the system integrator’s responsibility
to tailor the configuration parameters to the specific operating