Kapsch TrafficCom
CTM Ethernet Ports 1 and 2 pin out
Connector Type
8 pin RJ45 female
Lightning Suppression
Recommended on all pins.
Pin Number
Signal
Description
Diagram
1
BI_DA+
Bi-directional pair A +
2
BI_DA-
Bi-directional pair A -
3
BI_DB+
Bi-directional pair B +
4
BI_DC+
Bi-directional pair C +
5
BI_DC-
Bi-directional pair C -
6
BI_DB-
Bi-directional pair B -
7
BI_DD+
Bi-directional pair D +
8
BI_DD-
Bi-directional pair D -
SPM terminal block connections
Connector Type
Terminal block
Lightning Suppression
Recommended for all signal wires.
Terminal Number
Signal
Description
Diagram
1
CGND
chassis ground, shield
2
R-
Sync Rx (RS-422 -)
3
R+
Sync Rx (RS-422 +)
4
T+
Sync Tx (RS-422 +)
5
T-
Sync Tx (RS-422 -)
6
CGND
chassis ground, shield