Prerequisites: None.
1. Click the icon on the manage software page on the left side panel.
Result: The following dialog screen appears.
2. Click the Shut down button.
3. When the reader has completed an orderly software shut down set both CTM ON/OFF switches to OFF.
4. Set both PSM power switches to the off (0) position.
Manually switching a Reader to the redundant side
The Reader is manually switched between the primary and secondary sides. This is necessary, for
example, when recovering a Reader back to the Primary side when automatic recovery is not enabled.
Prerequisites: Ensure no faults exist on the side being activated.
1. Set the SPM redundancy mode switch to either SECONDARY or PRIMARY, as applicable.
Result: The ACTIVE LED on the CTM of the selected side illuminates green, indicating the selected side
is active.