Operations and Maintenance Manual

_
JANUS
®
Multi-Protocol Reader Ver. 2: Operating Instructions
Confidential UM 360450-210 Revision C Page 93 of 288
© Kapsch TrafficCom Canada Inc. 2014
These drawings and specifications contain confidential and proprietary information and are the property of Kapsch TrafficCom Canada Inc. and are issued in strict confidence and will be kept confidential and used solely for the purpose
intended and for no other purpose and shall not be transmitted, reproduced, copied, and/or used as the basis for manufacture or sale of apparatus unless otherwise agreed to in writing by Kapsch TrafficCom Canada Inc.
FILE: UM 360450-210 REV C JANUS MPR2 OPERATOR-MAINTENANCE MANUAL.DOCX 08/17/2015 11:42
Kapsch TrafficCom
Command
How is this command
executed?
Who can
execute this
command?
Parameter
Name
Default
Parameter
Value
Parameter
Range/Options
What does this
command do?
What is the
purpose of this
command?
Primary/Secondary
Redundant Mode
From the General tab
on the Configuration
page:
Select the Redundant
Mode check box..
user with
Advanced
User
permissions
RDNDNT
1 (Redundant
Mode enabled)
0 (Disabled)
Enabled)
Disabled: Reader does not
attempt to switch to
redundant side when a
failure occurs.
Enabled: Reader attempts
to switch to redundant
side when a failure occurs
(depending on
configuration)
Used to enable
the Reader to
automatically
switch over to
the redundant
side when a
failure occurs
Dual Reporting
Mode
From the General tab
on the Configuration
page:
Select the Dual
Reporting Mode check
box..
user with
Advanced
User
permissions
DUALRP
Dual Reporting
Mode disabled)
Dual Reporting
Mode
disabled)
Dual Reporting
Mode
enabled)
sets Reader to Dual
Reporting mode
Used to gather
reports from
both the primary
and secondary
sides of the
Reader
Auto Recovery To
Prime
From the General tab
on the Configuration
page:
Select the Auto
Recovery To Prime
check box.
user with
Advanced
User
permissions
A_RCVR
Auto Recovery
to Prime
Enabled)
Disabled)
Enabled)
Disabled: Reader does not
attempt to recover to
Primary side when failure
clears.
Enabled: Reader
automatically attempts to
recover to Primary side
when a Primary failure
clears.
to enable the
Reader to
automatically
switch back to
the primary side
once a primary
side failure has
cleared