Connecting the Antenna
NOTICE
Risk of malfunction!
When using a cable not suitable for the impedance of 50 Ohm, the performance of the
reader will be severely limited by the mismatch. If the mismatch is large, the reader may
indicate a fault.
Ź Only use cable suitable for the impedance (50 Ohm).
For the connection to the RFID antennas, the reader has four antenna connections that are of the reverse
TNC design.
Ź Only use the cable from the accessories or equivalent cable for this connection.
Turning the Reader On and Off
Ź Connect the reader to the power supply via a PWR or to a PoE source according to the 802.3at standard
via LAN /POE input.
߳The reader is on.
Reading the PWR LED Indications
The reader has a 2-colour LED for the indication of the operating state. The table below shows the colors
used and the related operating state:
LED Action Meaning
yellow on the unit is booting
green
yellow
on
flashing approx. every 8 seconds
unit is on, normal operation
with heartbeat
yellow
green
on
flashing approx. every 8 seconds
error during booting
Tipp
The SRU-8110 readers have additional 4 LEDs (green/red/red/green) in the antenna cover